Microcom 412 Manuel de l'opérateur Page 80

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 239
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 79
Printer Commands Chapter 5
5-14 428TC Operator’s Manual - 880041-0141
0 = Accept Incoming Control Codes
4 Port #1 Parity Selection: Sets the printer port #1 parity for serial
communication.
1 = Odd Parity
0 = Even Parity
5 Port #1 Parity Enable: Turns printer port #1 parity ON or OFF for serial
communication.
1 = Disable Parity (NONE)
0 = Enable Parity
6 Echo: If this feature is enabled, the printer will echo all received
characters to the serial port.
1 = Enable
0 = Disable
7 Number of Data Bits: Sets the printer’s serial port to use either 7 or 8
data bits.
1 = 8 Data Bits
0 = 7 Data Bits
8 XON/XOFF Flow Control: Sets software flow control handshaking.
CTS/RTS hardware handshaking is always enabled.
1 = Enable
0 = Disable
5.2.1.2 Software Switch #2
^AB ^D COMMAND
XX 22 Change SW2: Software Switch #2.
^AB12345678 (each bit is represented by a numeric position number)
Position:
1 Clear Text Function: If enabled, all variable text strings will be erased
when the ^D<CR> is processed.
1= Enable
0 = Disable
2 >RESTARTED< Response: If the printer has been reset and this
switch has been enabled, the printer will respond with the
>RESTARTED< message for the first enquiry ONLY, to denote the
reset condition and then >READY< with following enquiries.
1 = Enable (>RESTARTED< on first inquiry then >READY<)
0 = Disable (Always responds with >READY<)
3 Button Use: If set to a “1”, the printer will disable the Print Button.
1 = Disable
0 = Enable