Microcom 400 Manuel de l'opérateur Page 29

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 100
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 28
Chapter 4 Designing Labels Using LDS
400 Operators Manual
21
FEED DIRECTION
.125" OR 25 DOTS
THIS IS THE GAP VALUE
3" OR 600 DOTS LSY
THIS IS 0,0
MICROCOM
4" OR 800 DOTS LSX
X BEGINNING
Y BEGINNING
.0625" OR 12 DOTS
THIS IS THE WEB VALUE
4.4 LABEL HEADER
The header consist of eleven parameters. These parameters contain information about the label.
It is not necessary to enter information for all of the parameters: If a parameter is left blank, then
the default value will be used. A carriage return must follow the label header parameters.
The value of measurement for many of the header elements is the dot. There are 203 dots per
inch on a 400 print head (8 dots/mm). There is a maximum 832 dots in the X direction (width). The
Y direction (length) is virtually unlimited.
Most header parameters can be supplied using the auto-size command. (See section 5.3.3.)
Below is a list of the header element mnemonics and default values:
HFM, LSX, LSY, WEB, GAP, DPS, LCB, AGD, SPG, OFX, OFY
0, 832, 614, 13, 24, 35, 0, 1, 479, 0, 0
Label Header Parameters of a 4" X 3" Label
Figure 8
Vue de la page 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 99 100

Commentaires sur ces manuels

Pas de commentaire