13-20 428TM Operator’s Manual - 880042-0141
^A ^D COMMAND
X 155 Set Feed Speed: Sets the feed speed used with the D153 and D154
commands.
0 8.0 ips (inches per second)
1 7.5 ips
2 7.0 ips
3 6.5 ips
4 6.0 ips
5 5.5 ips
6 5.0 ips
7 4.5 ips
8 4.0 ips
9 3.5 ips
10 3.0 ips
11 2.5 ips
12 2.0 ips
13 1.5 ips
14 1.0 ips
X 156 Set Non-stick Time Interval: Sets the time interval for the Non-stick TOF
mode (D26 position 8). The value for X represents the number of seconds
that the printer will execute the Non-stick TOF operation. The default setting is
14400 or 4 hours. The valid range is from 2 to 65536.
X 157 Takeup Motor Run Time: Only used with custom Takeup PIC code. The
value for X represents how long the takeup motor will run, in milliseconds,
after printing has stopped.
0 0
1 25 25 msec
2 50
3 75
4 100
5 125
6 150
7 175
8 200
9 225
10 250
11 275
12 300
13 325
14 350
15 375
16 400
17 425
18 450
19 475
20 500
21 525
22 550
Vue de la page 233