Chapter 4 Designing Labels Using LDS
412 Operators Manual
21
4.4 LABEL HEADER
The header consist of eleven parameters. These parameters contain information about the
label. It is not necessary to enter information for all of the parameters: If a parameter is left
blank, then the default value will be used. A carriage return must follow the label header
parameters.
The value of measurement for many of the header elements is the dot. There are 203 dots per
inch on a 412 print head (8 dots/mm). There is a maximum 832 dots in the X direction (width).
The Y direction (length) is virtually unlimited.
Most header p
arameters can be supplied using the auto-size command. (See section 5.3.3.)
Below is a list of the header element mnemonics and their default values:
HFM,LSX,LSY,WEB,GAP,DPS,LCB,AGD,SPG,OFX,OFY
0,832,614, 13, 24, 35, 0, 1,478, 0, 0
Label Header Parameters of a 4" X 3" Label
Figure 7