^A ^D COMMAND
101 List Memory Bytes Available:
The printer will send the “>” character followed by the amount of available
bytes and then finally a “<” character. (i.e. >192690<)
XX 104 Load GRAPHIC or FONT into RAM Memory without Compression:
The ^Axx specifies which memory slot to place the image/font (1-255). This
command should be used with an ASCII-HEX file that contains only printable
characters less than 80 HEX. This command supports GRAPHICS over
64KB.
XX 106 Load GRAPHIC or FONT into RAM Memory without Compression:
This command is intended for legacy support only and Microcom Corporation
recommends either the ^D104 or ^D107 commands. Fonts must be less than
64KB for this command to function.